164,000 Colocation Footprint ft2
STRONG POINTS
SEE WHY SELECTING OUR SERVICES IN THIS DATACENTER WOULD BE PROFITABLE FOR YOU
CONNECTIVITY
100% Juniper based MPLS network. Metro blend of Telia, GTT, Telecom Italia/Sparkle, DE-CIX New York, Digital Realty IX New York upstreams delivered through AS62240. We also peer with a number of local ISP’s
POWER
Two utility feeds of 3700 kW from diverse substations — 150 W/ft2 of maximum power density. Backed by 1000 kW UPS and 6000 kW generators in N+1, 2N configuration. DC power available.
RELIABILITY
Diverse utility feeds. UPS, RPP, PDU N+1, 2N redundancy. Power Generators N+1 redundancy. N+1 cooling system. 100% concurrently maintainable. 24x7x365 Remote hands.
SECURITY
Key cards and biometric scanners. Perimeter and interior IP-DVR. Controlled datacenter access. 24x7x365 in-house and on-site security qualified personnel.
STRUCTURE
Collocation size 164000 ft2. Floor load of 125 lbs/ft2. Membrane and reinforced roof. Concrete Decking
FIRE SUPPRESSION
Dual-interlock pre-action dry-pipe sprinkler system with VESDA
A FEW WORDS ABOUT 60 HUDSON
60 HUDSON, NEW YORK DATACENTER ESSENTIAL INFORMATION
SO YOU CAN GET A BETTER PICTURE
Location,
Location!
Occupying multiple floors with interconnectivity between all
points, our site at 60 Hudson Street offers low-latency access to over 400 carriers, multiple financial exchanges, and application, media, content, and software-as-a-service providers within the building.
MORE FEATURES
FEATURES OF 60 HUDSON NEW YORK DATACENTER
Outside 500 year flood plain
Zone 2A
125 (lbs/ft2)
3,750 (kW)
150 (W/ft2)
Available
Multiple Diverse Entrances
1,000 (kW)
N+1, 2N
6000 (N+1) (kW)
24x7x365
N+1
N+1
N+1
Membrane and Reinforced
Concrete Decking
Roof Rights Available – ICB
NETWORK CHARACTERISTICS
OUR NYC METRO NETWORK BLEND CURRENTLY
CONSISTS OF THE FOLLOWING UPSTREAMS DELIVERED OVER AS62240
Telia
GTT
Telecom Italia/Sparkle
DE-CIX New York
Digital Realty IX New York
We also peer with number of local ISP’s
DETAILED SPECIFICATION
FURTHER DETAILS ABOUT 60 HUDSON DATACENTER
TO GIVE YOU ALL INFORMATION NEEDED
Two utility feeds of 3750 kW from diverse substations — 150 W/ft2 of maximum power density.
Backed by 1000 kW UPS and 6000 kW generators in N+1, 2N configuration. With 24 hours, on-site with multiple refuelling contracts. DC power is also available.
N+1 cooling room redundancy and N+1 cooling equipment.
The datacenter is equipped with Heat and Smoke detectors above the head and under the floor.
Systems are tied back to the building Class-E systems connected back to the FDNY and monitored 24x7x365.
Pre-Action Dry Pipe System fixed above the head.
Walls are fire-rated for 2 hours. Also, personnel is 24x7x365 at these locations.
Our network metro blend in 60 Hudson is a 100% Juniper based MPLS network and currently consists of Telia, GTT, Telecom Italia/Sparkle, DE-CIX New York, Digital Realty IX New York upstreams delivered through AS62240. We also peer with a number of local ISP’s.
Wireless Network available through the facility. Access to Tech-Lounge – On-site kitchenette.
SOC, 2SOC, 3PCI-DSS
SOC 2 Mapping: NIST 800-53, HIPAA, and ISO 27001
Biometric / Photo Badge Access. CCTV with 90-day backup. 24x7x365 in-house and on-site security qualified personnel.