Colocation size 144,560 ft2
STRONG POINTS
SEE WHY SELECTING OUR SERVICES IN THIS DATACENTER WOULD BE PROFITABLE FOR YOU
CONNECTIVITY
100% Juniper based MPLS network. Metro network mix of best Tier-1 Routes.
POWER
Equinix DA11 offers average power density 5 - 12 kVA per cabinet. Feed incoming from two separate supplies. Backed by Parallel redundant N+2 two x 1,200 kVA UPS and 6 x 3000 kW diesel generators.
RELIABILITY
Diverse utility feeds. UPS N+2redundancy. Power Generators N+2 redundancy. Cooling redundancy N+2 24x7x365 Remote hands.
SECURITY
Man trap entry. 24/7 on-site security officers. Biometric readers, fiber vault, CCTV surveillance with 90-day retention, motion detection.
STRUCTURE
Colocation size 144,560 ft2 Slab floor type with 250 psf max load. Building: 4-story steel frame with pre-cast concrete exterior.
FIRE SUPPRESSION
Double-interlocked pre-action
A FEW WORDS ABOUT EQUINIX DA11
EQUINIX DA11 DATACENTER ESSENTIAL INFORMATION
SO YOU CAN GET A BETTER PICTURE
Location,
Location!
The Dallas-Fort Worth region has long been a major Internet and Network Peering Exchange Point. The Equinix Datacenter utilises its strategic location, making it the foremost hub for communication providers in the Southwest, with quick access to Latin American routes.
MORE FEATURES
FEATURES OF EQUINIX DALLAS DATACENTER
Low
Low
250 psf
5 – 12 kVA per cabinet.
5 – 12kVA per cabinet
N+2
Network Density
Five power blocks (four primary and one reserve) each with 2 x 1,200 kVA UPS modules. Block redundant configuration.
N+2
6 x 3,000 kW diesel generators in
parallel configuration (N+2)
24x7x365
NETWORK CHARACTERISTICS
OUR DALLAS METRO NETWORK BLEND CURRENTLY
CONSISTS OF THE FOLLOWING UPSTREAMS DELIVERED OVER AS62240 VIA MPLS
Telia
GTT
Equinix IX Dallas
Telecom Italia/Sparkle
We also peer with number of local ISP’s
DETAILED SPECIFICATION
FURTHER DETAILS ABOUT DALLAS DATACENTER
TO GIVE YOU ALL INFORMATION NEEDED
DA11 Dallas IBX Data Center offers 5 to 12 kVA per cabinet from two separate 1utility feeds. Backed by Parallel redundand N+2 2 x 1,200 kVA UPS configuration and 2 x
2,500 kVA and 6 x 3,000 kW diesel generators in parallel configuration.
High-efficiency water-cooled chillers with side-discharge air handling units. N+2 cooling redundancy.
Double-interlocked pre-action.
Double-interlocked pre-action.
Our network metro blend in Dallas Equinix DA11 currently consists of: #networklist
upstreams delivered through AS62240. We also peer with number of local ISP’s
Breakroom
Conference Rooms(s)
Crash Carts
Loaner tools
Showers
Wifi
Work Kiosks
SOC 1 Type II
SOC 2 Type II
ISO 27001
NIST 800-53/FI
PCI DSS
HIPPA
Man trap entry. 24/7 on-site security officers. Biometric readers, fiber vault, CCTV surveillance with 90-day retention, motion detection.